Certification: | TüV, ISO9001, CE |
---|---|
Application: | Transformer Oil |
Voltage: | According to Demand220V/380/440V |
Folw Rate: | 50 L/min |
Work Principle a: | Vacuum Oil Dehydration |
Work Principle B: | Vacuum Oil Degassing |
Customization: |
---|
Suppliers with verified business licenses
Dust Proof Type 1 Micron Filter Transformer Oil Processing Machine 3000LPH
Application:
REXON Dust Proof Type 1 Micron Filter Transformer Oil Processing Machine 3000LPH, Strong Vacuum Dehydrating Transformer Oil Purifier, series high- efficiency double stage vacuum oil purifier is a typical product, develop and produced by REXON Co. as especial equipment for dehydration, degassing, purification process of various kind of insulation oils in electrical transformers and circuit breakers etc,. it is designed on vacuum drying principle, accurate fine filtration and other modern technique. REXON ZYD-50 Transformer Oil Purifier Machine is a machine for power plant and substation that specializes in the vacuum filtration of transformer oil. The machine can go out of the water, gas, impurities and other pollutants in the transformer oil, so that the oil can reach the qualified index and can be used in the transformer. Also it can inject the insulating oil into the transformers on-line. The ZYD system provides regular oil purification such as degassing, drying and particulate removal but also can remove acidity, sludge, other soluble oil decay products and discoloration.
Feature:
1. Especially for removing water from transformer oil, such as free water, trace water and so on by the double stage vacuum system for high voltage oil.
2. Remove gas, air content from the old high voltage transformer oil by vacuum degassing system.
3. Remove impurities, tiny particles, acidity, sludge, free carbon, other soluble oil decay products and discoloration substances by 3 stages of filters (Primary filter, secondary filter, fine filter).
4. Independent vacuum oiling system for transformers, this oil purifier can also vacuum dry transformer and on-line operation with transformers.
5. Designed for processing high voltage insulating oils in workshops, onsite power stations, purifying oil in oil storage tanks or directly in transformers(energized or de-energized transformers).
6. Efficient electric heating system, heating uniformity, less power consumption, safe, and reliable.
7. Double-infrared liquid level sensor, pressure protective system and foaming detecting and eliminating to ensure machine operation easily and safely.
8.Adopt interlocked protective system, which connect oil pump, heater and liquid level sensor, avoiding blank heating, blank pumping.
Advantage:
Dust Proof Type 1 Micron Filter Transformer Oil Processing Machine 3000LPH, trace water, gas, particles as well as acetylene, hydrogen, methane and other harmful ingredients from oil effectively to improve oil's dielectric strength, effectively making sure electric equipment working safely and normally.
REXON ZYD oil purifier series is mainly used to improve the properties of insulation oil. It can remove trace water, gas, particulate matters etc. from the insulating oil effectively and rapidly so as to boost performance of transformers, circuit breakers, mutual inductors, cable and capacitors which has insulation system. ZYD series specialize in filtering branded oil, insulating oil of high voltage and super high voltage transformer. Additionally, it is suitable for recycling low viscosity lubrication oil.
Technical Parameters:
Parameters | Unit | ZYD-30 | ZYD-50 | ZYD-100 | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 | |
Flow Rate | L/H | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Working Vacuum | Mpa | -0.08 ~-0.099 | |||||||
Working Pressure | Mpa | ≤ 0.3 | |||||||
Temp Range | ºC | 20 ~80 | |||||||
Power Supply | 380V, 50Hz, 3Phase( As per required) | ||||||||
Working Noise | Db | 60 - 80 (Depended on the configuation) | |||||||
Heating Power | KW | 30 | 30 | 48 | 72 | 72 | 90 | 120 | |
Total Power | KW | 33 | 35 | 55 | 80 | 82 | 102 | 135 | |
Inlet/Outlet Diam | MM | 25 | 32 | 42 | 50 | 50 | 60 | 60 | |
Weight | KG | 450 | 550 | 750 | 950 | 1200 | 1850 | 2000 | |
Size | Length | MM | 1450 | 1450 | 1750 | 1850 | 1950 | 2050 | 2150 |
Width | MM | 950 | 1000 | 1250 | 1300 | 1350 | 1400 | 1450 | |
Height | MM | 1700 | 1750 | 1950 | 2000 | 2050 | 2100 | 2150 | |
AFTER TREATMENT | |||||||||
Dielectric Strength | KV | ≥ 75-85 | |||||||
Water Content | PPM | ≤ 3 | |||||||
Gas Content | % | ≤ 0.1 | |||||||
Particle Size | μ | ≤ 3 | |||||||
Cleanliness ≤NAS 1638 Grade 5 |
Product Introduction:
REXON high vacuum dehydration transformer oil filtration machine adopts two-stage high vacuum system, high efficiency three-stage filter system, high-power low-temperature heating system, constant temperature heating control system, intelligent electronic control system, PLC control system, automatic oil level The detection system, the vacuum detection system, and the safety protection system, etc., REXON machines are constructed using the latest oil filtering technology and internationally renowned brand accessories.
1. Free operation manuals and videos: Each product is produced according to the customer's customized requirements. We will provide you with free operation manuals and videos so that you can better understand the usage and operating procedures of the product.
2. Free online guidance: If you encounter any problems when using the product, our technical support team will provide online guidance at any time to help you solve the problem.
3. Lifetime free technical support: We promise to provide you with life-long free technical support, including technical consultation, repair and maintenance support.
4. On-site debugging and training: We can send professional engineers for on-site debugging and provide training for you and your team to ensure that you can use the product correctly and achieve the best results.
Suppliers with verified business licenses