Portable Oil Particle Counter for Industrial Oil Contaminants Testing
Description
REXON LPC-P6 portable oil particle counter is designed on the principle of light resistance (shading method) and is used to detect the size and number of particles in the liquid. It can be widely used in aerospace, aviation, electric power, petroleum, chemical industry, traffic, port, metallurgy, machinery, automobile manufacturing and other fields in the hydraulic oil, lubricating oil, transformer oil, insulating oil, turbine oil, gear oil, engine oil, aviation kerosene, water-based hydraulic fluid solid particle pollution tests such as oil, And the detection of insoluble particles in organic liquid and polymer solution.
Features
Light-blocking (shading) test principle specified by the International Hydraulic Standards Committee.
High-precision laser sensor, wide test range, stable performance, low noise, high resolution.
The pipeline is made of 316L and PTFE materials, which are corrosion-resistant and meet the detection of various organic solvents and oils.
For laboratory or on-site measurement, optional pressure relief device for online high-pressure measurement.
Can be connected to an external pressure chamber to form positive/negative pressure, realizing the detection of high-viscosity samples and negative pressure degassing of samples.
Can use a variety of sampling containers such as standard sampling bottles and sampling cups, or directly connect to the hydraulic system for online testing to meet the testing requirements of different industries.
Built-in multiple calibration curves, compatible with all commonly used domestic and foreign standards for calibration.
Can perform automatic calibration, manual calibration and half-count calibration.
Built-in GJB-420A, GJB-420B, NAS1638, GB/T14039, ISO4406, SAE4059cpc, SAE4059F, SAE749D, ГOCT17216, QC/T29 104, JB/T9737, DLT432, HH005-2018 and more than ten commonly used standards. One test can give data results under all built-in standards.
Supports custom standard testing, and can set 64 detection channels at the same time according to customer needs.
1000 particle size channels can be set for easy particle size analysis.
Built-in data analysis system, which can automatically determine the sample grade according to the standard, with automatic data processing and printing functions.
7-inch color touch screen operation, Chinese and English input, free switching language interface, with preset, input, modification, storage, upload functions, convenient and fast operation.
Can set multiple user login accounts at will, can add new users, set permissions and delete old users.
Optional tablet computer control, win10 operating system, can edit personal signatures for operators.
With RS232 interface, can be connected to a computer or laboratory platform for data processing, and can also use USB for data storage.
Built-in lithium battery, suitable for field operations, can be used without external power supply.
Embedded design, high-strength shell, easy to carry, suitable for all kinds of engineering machinery.
Technical Index
Light source: semiconductor laser
Particle size range: 0.8-600μm (calibrated according to ACFTD calibration 1~100μm or ISO MTD calibration 4~70μm(c))
Detection channels: 64, arbitrarily set particle size
Sampling volume: 0.2-1000ml
Sampling accuracy: better than ±1%
Sampling speed: 5-80mL/min
Cleaning speed: 5-80mL/min
Cleaning volume: can be set between 0ml and 90ml
Counting accuracy: error less than ±5%
Resolution: ≤10%
Repeatability: RSD<2%
Limit coincidence error: 12000-40000 particles/mL
Temperature acquisition (optional): -40~100ºC Accuracy: ±0.5ºC
Moisture (optional): Water activity acquisition: 1~100%RH; Accuracy: ±1%RH
Absolute water content: 1~360ppm; Accuracy: ±10ppm
Viscosity (optional): 0.5~500 cSt Accuracy: ±2%
Offline detection viscosity: ≤100cSt (optional pressure bottle sampler with maximum viscosity up to 400cSt)
Pressure range: low pressure 0-0.6MPa, high pressure up to 42MPa (optional pressure reducing valve)
Online detection interval: arbitrarily set
Instrument screen size: 7 inches
Tablet size: 10 inches (optional)
Tablet system: win10 professional system TYPE-C to DB9 data cable connected to the instrument serial port
Flash: 64GB
RAM: not less than 4GB DDR3L
Test sample temperature: 0ºC~80ºC
Working temperature: -20ºC~60ºC
Storage temperature: -30ºC~80ºC
Power supply: AC100-240V, 50/60Hz
Battery capacity: 5200mAh
Battery operation time: 6-8 hours
Dimensions: 420×326×182mm
Weight: 9kg
Detailed Photos Other Oil Testers We Supply: Miosture Tester Viscosity Tester
We are the biggest leading manufacture of oil purifiers for all kinds of used or new oils in China. We supply best quality machines and offer professional technical support, A-class after-sales-service for customers. Our price is competitive and we take responsibility to guarantee any quality uncertainty. We design and produce our oil purifier machines with high quality raw materials and mature-technology by lots of well qualified technicians and skilled workers.
RECOMMEND PRODUCTS
For Insulating Oil (transformer oil, mutual inductor oil, valve oil and so on) -Highly Effective Vacuum Oil Purifier -Computer-Tested Highly Effective Vacuum Oil Purifier (ZY with oil tester) -Mobile Type Multi-function Transformer Oil Treatment Machine -Automatic Double-Stage Highly Effective Vacuum Transformer Oil Purifier -Ultra-High Voltage Oil Regeneration Treatment
For more information about any model of our oil purifier's specs, please leave us your Email, Tel, Mobile No. etc. then we can feedback to you immediately. Or you can contact us directly from our website. Don't hesitate to send us enquiry now. And you are welcome to visit us!