Customization: | Available |
---|---|
Certification: | TüV, ISO9001, CE |
Application: | Transformer Oil |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Transformer Oil/ Insulating Oil High Precision Filtration Machine
Brief Introduction:
Machine Condition: New
Treatment Capacity: 3000 L/H
Working Pressure: ≤0.4 Mpa
Place of Origin: Chongqing, China (Mainland)
Brand Name: REXON OIL PURIFICATION
Model Number: ZYD-50
Application: Transformer Oil
Power data: 380V 50HZ/3 Phase Or As Required
Function: Vacuum oil dehydration and degassing, oil filtering, removing particles, free water, dissolved water, gas, acidity completely.
After-sales Service: Free factory training & Engineers available for on-site commissioning.
Warranty: 2 Years
Oil Data After Process:
Impurity size after process: ≤1 micron
Gas content after process: ≤0.1%
Moisture content after process: ≤3 PPM
Product Introduction:
Our vacuum transformer oil purifier is developed on the characteristics of oil for electricity, especially for special high-voltage transformers above 110kv facilities. We successfully created the most advanced and best special insulating oil treatment equipment. Oil purification standard reaches Q/GDW122-2005. After several improvements, the device has reached the domestic leading level and international similar products in the same performance parameters, with a high price-performance ratio.
This product is a combination of the international advanced film theory and atomized oil treatment technology, with a highly efficient degassing dehydration and breaking emulsification effect. Oil in this system is fully thin-film (Oil exposed areas are fully expanded), and oil increases the "journey" so that water or gas in oil is vaporized for sufficient time to reach the best effect of dehydration degassing.
The device uses electronic anti-foaming devices and high-efficiency needle-breaking foam technology to eliminate foam (patented technology) and make no "injection" phenomenon during operation.
Adopting the "Y-type" gear pump, guide wheel technology (patented technology) and VFD driving technology, we solved oil-drain problems in high-vacuum and noise problems.
Application:
REXON High Precision Filtered Transformer Oil Purifier Machine, Strong Vacuum Dehydrating Transformer Oil Purifier, series high- efficiency double stage vacuum oil purifier is a typical product, develop and produced by REXON Co. as especial equipment for dehydration, degassing, purification process of various kind of insulation oils in electrical transformers and circuit breakers etc,. it is designed on vacuum drying principle, accurate fine filtration and other modern technique. REXON ZYD-50 Transformer Oil Purifier Machine is a machine for power plant and substation that specializes in the vacuum filtration of transformer oil. The machine can go out of the water, gas, impurities and other pollutants in the transformer oil, so that the oil can reach the qualified index and can be used in the transformer. Also it can inject the insulating oil into the transformers on-line. The ZYD system provides regular oil purification such as degassing, drying and particulate removal but also can remove acidity, sludge, other soluble oil decay products and discoloration.
Feature:
1. Especially for removing water from transformer oil, such as free water, trace water and so on by the double stage vacuum system for high voltage oil.
2. Remove gas, air content from the old high voltage transformer oil by vacuum degassing system.
3. Remove impurities, tiny particles, acidity, sludge, free carbon, other soluble oil decay products and discoloration substances by 3 stages of filters (Primary filter, secondary filter, fine filter).
4. Independent vacuum oiling system for transformers, this oil purifier can also vacuum dry transformer and on-line operation with transformers.
5. Designed for processing high voltage insulating oils in workshops, onsite power stations, purifying oil in oil storage tanks or directly in transformers(energized or de-energized transformers).
6. Efficient electric heating system, heating uniformity, less power consumption, safe, and reliable.
7. Double-infrared liquid level sensor, pressure protective system and foaming detecting and eliminating to ensure machine operation easily and safely.
8.Adopt interlocked protective system, which connect oil pump, heater and liquid level sensor, avoiding blank heating, blank pumping.
Advantage:
High Precision Filtered Transformer Oil Purifier Machine, trace water, gas, particles as well as acetylene, hydrogen, methane and other harmful ingredients from oil effectively to improve oil's dielectric strength, effectively making sure electric equipment working safely and normally.
REXON ZYD oil purifier series is mainly used to improve the properties of insulation oil. It can remove trace water, gas, particulate matters etc. from the insulating oil effectively and rapidly so as to boost performance of transformers, circuit breakers, mutual inductors, cable and capacitors which has insulation system. ZYD series specialize in filtering branded oil, insulating oil of high voltage and super high voltage transformer. Additionally, it is suitable for recycling low viscosity lubrication oil.
The REXON Multi-Function Transformer Oil Filtration Machine is an oil processing equipment designed to treat used transformer oil and give it a new life. The machine has the function of dehydrating, degassing, purifying, filtering and regenerating the transformer oil. Therefore, the moisture, gas and impurity contaminants in the transformer oil will be removed after being purified by our transformer oil filter.
Vacuum Dehydration(Degas) system:
Our Double-horizontal vacuum evaporation vessels can enlarge evaporation area efficiently. The heater, being places in the vacuum vessels, becomes an evaporator. Thus the evaporation areas of Double-horizontal vacuum vessels are three times more than of the common vacuum vessel. This innovation can dehydrate and degas effectively and separately. This optimal structure of the dehydration (degas) system enlarge the surface area of oil exposed to the vacuum system and extends the flowing distance of the oil in the vacuum system. Thus there has sufficient time to remove the moisture and gas from the oil by vaporization.
Parameters | Unit | ZYD-30 | ZYD-50 | ZYD-100 | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 | |
Flow Rate | L/H | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Working Vacuum | Mpa | -0.08 ~-0.099 | |||||||
Working Pressure | Mpa | ≤ 0.3 | |||||||
Temp Range | ºC | 20 ~80 | |||||||
Power Supply | 380V, 50Hz, 3Phase( As per required) | ||||||||
Working Noise | Db | 60 - 80 (Depended on the configuation) | |||||||
Heating Power | KW | 30 | 30 | 48 | 72 | 72 | 90 | 120 | |
Total Power | KW | 33 | 35 | 55 | 80 | 82 | 102 | 135 | |
Inlet/Outlet Diam | MM | 25 | 32 | 42 | 50 | 50 | 60 | 60 | |
Weight | KG | 450 | 550 | 750 | 950 | 1200 | 1850 | 2000 | |
Size | Length | MM | 1450 | 1450 | 1750 | 1850 | 1950 | 2050 | 2150 |
Width | MM | 950 | 1000 | 1250 | 1300 | 1350 | 1400 | 1450 | |
Height | MM | 1700 | 1750 | 1950 | 2000 | 2050 | 2100 | 2150 | |
AFTER TREATMENT | |||||||||
Dielectric Strength | KV | ≥ 75-85 | |||||||
Water Content | PPM | ≤ 3 | |||||||
Gas Content | % | ≤ 0.1 | |||||||
Particle Size | μ | ≤ 3 | |||||||
Cleanliness ≤NAS 1638 Grade 5 |
Why Need Rexon Oil Purifier?
Present and future transformer ratings require high quality and high purity insulating oils at the point of use. The increasing voltage and rating of the modern transformer and electrical apparatus results in greater electrical stress in insulating material and fluids. To handle these greater stresses, oils with better dielectric qualities are required. Also lower residual water content in insulating fluids and material must be maintained. The proper treatment and upgrading of the insulating fluid will result in the improvement of the properties of the entire insulating media of power transformers. The principal functions of the insulating fluid are to serve as a dielectric material and as an effective coolant. To perform these functions, the insulating fluid must have the necessary qualities at the time of initial impregnation and filling at the factory and later maintain the same quality in the field operation.
For Insulating Oil
(transformer oil, mutual inductor oil, valve oil and so on)-Highly Effective Vacuum Oil Purifier -Computer-Tested Highly Effective Vacuum Oil Purifier (ZY with oil tester) -Mobile Type Multi-function Transformer Oil Treatment Machine -Automatic Double-Stage Highly Effective Vacuum Transformer Oil Purifier -Ultra-High Voltage Oil Regeneration Treatment |
For Lubricant Oil
(hydraulic oil, turbine oil, gear oil, diesel, heating oil and so on)-Multi-function Lubricating Oil Purifier -Highly Effective Vacuum Turbine Oil Purifier -Hydraulic Regeneration Oil Purifier -Coalescence-Separation Diesel Oil /Light Oil Purifier -Centrifugal Vacuum Oil Purifier -Phosphate Ester Fire-Resistant Oil Purifier |
Other Kind Plants related:
-Highly Effective Vacuum Engine Oil Purification System-Portable Oil Purifier -Plate Pressure Oil Purifier -Highly Effective Oil Filling Machine -Small Portable Edible Oil Filtration Machine -Transformer Oil BDV (Breakdown Voltage) Tester -Automatic Particle Counter -Automatic Moisture Tester -SF6 Analyser |