High Vacuum Insulating Oil Purifier Frame Stype 6000LPH
What can REXON Vacuum Insulating Oil Purifier do?
ZYD vacuum insulating oil purifier can remove the water, gas and impurities from insulation oil high-efficiently, increasing the pressure force and quality of oil, make the oil limiting voltage-withstand value much higher and make sure the electric device running safely.
Application:
REXON Vacuum Insulating Oil Purifier is mainly used for electric power department and industries to deal with various oils such as transformer oil, mutual oil, switch oil, insulating oil, dielectric oil and so on. The transformer oil purifier machine is especially for purifying the insulation oil in all kinds of large power equipment that are above 110KV, especially for the altitude is over 500-1000 meters. Our transformer oil filtration unit can remove the free and dissolved water, gas and particles from oil high-efficiently, and improve dielectric value of treated oil to be higher than 75~85KV, and increase the pressure force and quality of oil, make sure the electric device running safely. This oil purification system is very suitable for the large power electric equipment and transformers.
Feature:
1. Especially for removing water from transformer oil, such as free water, trace water and so on by the double stage vacuum system for high voltage oil.
2. Remove gas, air content from the old high voltage transformer oil by vacuum degassing system.
3. Remove impurities, tiny particles, acidity, sludge, free carbon, other soluble oil decay products and discoloration substances by 3 stages of filters (Primary filter, secondary filter, fine filter).
4. Independent vacuum oiling system for transformers, this oil purifier can also vacuum dry transformer and on-line operation with transformers.
5. Designed for processing high voltage insulating oils in workshops, onsite power stations, purifying oil in oil storage tanks or directly in transformers(energized or de-energized transformers).
6. Efficient electric heating system, heating uniformity, less power consumption, safe, and reliable.
7. Double-infrared liquid level sensor, pressure protective system and foaming detecting and eliminating to ensure machine operation easily and safely.
8.Adopt interlocked protective system, which connect oil pump, heater and liquid level sensor, avoiding blank heating, blank pumping.
Advantage:
This unit can quickly remove water, trace water, dissolved gas, particles as well as acetylene, hydrogen, methane and other harmful ingredients from oil effectively to improve oil's dielectric strength, effectively making sure electric equipment working safely and normally. As the bridge-type vacuum linking system that also can be an independent vacuum power supply, which can vacuuming and oil injecting for electric insulation devices.
Technical Parameters:
Parameters | Unit | ZYD-30 | ZYD-50 | ZYD-100 | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 | |
Flow Rate | L/H | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Working Vacuum | Mpa | -0.08 ~-0.099 | |||||||
Working Pressure | Mpa | ≤ 0.3 | |||||||
Temp Range | ºC | 20 ~80 | |||||||
Power Supply | 380V, 50Hz, 3Phase( As per required) | ||||||||
Working Noise | Db | 60 - 80 (Depended on the configuation) | |||||||
Heating Power | KW | 30 | 30 | 48 | 72 | 72 | 90 | 120 | |
Total Power | KW | 33 | 35 | 55 | 80 | 82 | 102 | 135 | |
Inlet/Outlet Diam | MM | 25 | 32 | 42 | 50 | 50 | 60 | 60 | |
Weight | KG | 450 | 550 | 750 | 950 | 1200 | 1850 | 2000 | |
Size | Length | MM | 1450 | 1450 | 1750 | 1850 | 1950 | 2050 | 2150 |
Width | MM | 950 | 1000 | 1250 | 1300 | 1350 | 1400 | 1450 | |
Height | MM | 1700 | 1750 | 1950 | 2000 | 2050 | 2100 | 2150 | |
AFTER TREATMENT | |||||||||
Dielectric Strength | KV | ≥ 75-85 | |||||||
Water Content | PPM | ≤ 3 | |||||||
Gas Content | % | ≤ 0.1 | |||||||
Particle Size | μ | ≤ 3 | |||||||
Cleanliness ≤NAS 1638 Grade 5 |